To simplify the ipdbg start/stop command and be able to
add additional commands in the future, we introduce the
concept of a hub which has to be created before a
ipdbg server can be started.
The hub was created on the fly in previous versions.
Change-Id: I55f317542d01a7324990b2cacd496a41fa5ff875
Signed-off-by: Daniel Anselmi <danselmi@gmx.ch>
Reviewed-on: https://review.openocd.org/c/openocd/+/7979
Reviewed-by: Antonio Borneo <borneo.antonio@gmail.com>
Tested-by: jenkins
Add access to dsp registers and a command for dsp related operations.
Checkpatch-ignore: MACRO_ARG_REUSE
Change-Id: I30aec0b9e4984896965edb1663f74216ad41101e
Signed-off-by: Walter Ji <walter.ji@oss.cipunited.com>
Reviewed-on: https://review.openocd.org/c/openocd/+/7867
Tested-by: jenkins
Reviewed-by: Oleksij Rempel <linux@rempel-privat.de>
Reviewed-by: Antonio Borneo <borneo.antonio@gmail.com>
The command substantially complicates support of nRF53/91
series. It was not even properly ported to nRF52.
The informative value is disputable. Who wants to see
e.g. override trim values for radio or unique device ID?
Drop it and simplify the driver.
Change-Id: Ia7fb20ce2ebf16065705c5d18deaf934e58db426
Signed-off-by: Tomas Vanek <vanekt@fbl.cz>
Reviewed-on: https://review.openocd.org/c/openocd/+/8108
Tested-by: jenkins
Reviewed-by: Antonio Borneo <borneo.antonio@gmail.com>
Add more debug messages connected with triggers.
Update names for internal flags to make them more clarified.
Change-Id: I5642346ce4a1e9bf79b22cdbf36bd757a7beffa8
Signed-off-by: Kirill Radkin <kirill.radkin@syntacore.com>
Prior to the change when calling `log_output` without any arguments it
was unclear where the log was redirected.
Change-Id: Iaa3ecea8166f9c7ec8aad7adf5bd412799f719a1
Signed-off-by: Evgeniy Naydanov <evgeniy.naydanov@syntacore.com>
Reviewed-on: https://review.openocd.org/c/openocd/+/8071
Tested-by: jenkins
Reviewed-by: Antonio Borneo <borneo.antonio@gmail.com>
Enable support for USB vid and pid combinations other than 0x0403/0x6001
on OpenJTAG adapters.
Change-Id: Ibb5fb14a6f33abbc011dbf3179df20d79ed74a7a
Signed-off-by: N S <nlshipp@yahoo.com>
Reviewed-on: https://review.openocd.org/c/openocd/+/8100
Tested-by: jenkins
Reviewed-by: Antonio Borneo <borneo.antonio@gmail.com>
S32K General-Purpose Microcontrollers
Scalable, low-power Arm® Cortex®-M series-based microcontrollers AEC-Q100
qualified with advanced safety and security and software support for
industrial and automotive ASIL B/D applications in body, zone control,
and electrification.
Change-Id: I4143258535437c18b81802436267bfd561de9d31
Signed-off-by: David Vidrie Leon <davidvidrie@geotab.com>
Reviewed-on: https://review.openocd.org/c/openocd/+/8012
Reviewed-by: Tomas Vanek <vanekt@fbl.cz>
Tested-by: jenkins
Add detection for mips cpu types by using prid.
Add cpuinfo command for inspecting more verbose info.
Add MIPS Architecture specs in openocd docs.
Change-Id: I28573b7c51783628db986bad0e226dcc399b4fa6
Signed-off-by: Walter Ji <walter.ji@oss.cipunited.com>
Reviewed-on: https://review.openocd.org/c/openocd/+/7912
Tested-by: jenkins
Reviewed-by: Antonio Borneo <borneo.antonio@gmail.com>
Reviewed-by: Oleksij Rempel <linux@rempel-privat.de>
Tested with APM32F030C8T.
Change-Id: I63cd8b66424135dae481a96ba560e6f0b1f9544e
Suggested-by: Christian U <info@cu-tec.de>
Signed-off-by: Marc Schink <dev@zapb.de>
Reviewed-on: https://review.openocd.org/c/openocd/+/8014
Tested-by: jenkins
Reviewed-by: Tomas Vanek <vanekt@fbl.cz>
Reviewed-by: Antonio Borneo <borneo.antonio@gmail.com>
Some devices with an internal multi-tap JTAG router require a vendor
specific bypass instruction to bypass the master TAP when addressing
slave taps internal to the same device. On these devices the standard
bypass instruction bypasses the whole device.
Change-Id: I4506f0e67c9e4dfe39b7fa18c63d67900313e594
Signed-off-by: Henrik Nordström <henrik.nordstrom@addiva.se>
Reviewed-on: https://review.openocd.org/c/openocd/+/8041
Reviewed-by: Antonio Borneo <borneo.antonio@gmail.com>
Tested-by: jenkins
If the remote_bitbang host does not execute requests immediately,
delays performed inside OpenOCD can be lost. This option allows
the delays to be sent to the remote host so that they can be
queued and executed in order.
Signed-off-by: Jeremy Herbert <jeremy.006@gmail.com>
Signed-off-by: David Ryskalczyk <david.rysk@gmail.com>
Change-Id: Ie1b09e09ea132dd528139618e4305154819cbc9e
Reviewed-on: https://review.openocd.org/c/openocd/+/7472
Tested-by: jenkins
Reviewed-by: Antonio Borneo <borneo.antonio@gmail.com>
Introduce 'cmsis-dap quirk' command to enable and
disable quirk mode.
If enabled, disconnect and connect before a switch
sequence and do not use multiple packets pipelining.
Change-Id: I6576f7de9f6c98a25c3cf9eec9a456a23610d00d
Signed-off-by: Tomas Vanek <vanekt@fbl.cz>
Reviewed-on: https://review.openocd.org/c/openocd/+/7966
Tested-by: jenkins
This adds new command characters to make SWD work with the new split
jtag and swd operations of bitbang.
The command characters are as follows:
O - SWDIO drive 1
o - SWDIO drive 0
c - SWDIO read request
d - SWD write 0 0
e - SWD write 0 1
f - SWD write 1 0
g - SWD write 1 1
Documentation has been updated accordingly. The new commands will be
used by an adapted version of the jtag-openocd applet of the "Glasgow
Debug Tool" (https://github.com/glasgowEmbedded/Glasgow). It has been
tested against an stm32f103 and an at91samd21 target.
contrib/remote/bitbang/remote_bitbang_sysfsgpio.c has also been adapted
to support SWD via the new command set. Some limited testing has been
done using a Raspberry Pi 2 with an stm32f103 and an at91samd21 target
attached.
Change-Id: I8e998a2cb36905142cb16e534483094cd99e8fa7
Signed-off-by: Manuel Wick <manuel@matronix.de>
Signed-off-by: David Ryskalczyk <david.rysk@gmail.com>
Reviewed-on: https://review.openocd.org/c/openocd/+/6044
Tested-by: jenkins
Reviewed-by: Tomas Vanek <vanekt@fbl.cz>
Reviewed-by: Antonio Borneo <borneo.antonio@gmail.com>
While at it, fix the 'wp' command documentation.
Change-Id: I70f3110e8ce286051f8f810260f1857b2285e634
Signed-off-by: Marc Schink <dev@zapb.de>
Reviewed-on: https://review.openocd.org/c/openocd/+/8022
Tested-by: jenkins
Reviewed-by: Antonio Borneo <borneo.antonio@gmail.com>
Reviewed-by: Jan Matyas <jan.matyas@codasip.com>
This is useful when using the SEGGER RTT tooling, as the SEGGER RTT
tool J-Link RTT Viewer version 7.84f requires that it receives a
messages immediately after connecting. Otherwise it will give a timeout
and it will not connect.
Change-Id: I9240a1b6a93cd5c0fbd18292afb33b89013d78bf
Signed-off-by: Thiemo van Engelen <tvanengelen@victronenergy.com>
Reviewed-on: https://review.openocd.org/c/openocd/+/7752
Tested-by: jenkins
Reviewed-by: zapb <dev@zapb.de>
Reviewed-by: Antonio Borneo <borneo.antonio@gmail.com>
Use a command group 'kitprog' with subcommands instead of individual
commands with 'kitprog_' prefix.
The old command is still available to ensure backwards compatibility,
but is marked as deprecated.
Change-Id: I7f0d447939819ffc488a3d7a8de672b58887127f
Signed-off-by: Marc Schink <dev@zapb.de>
Reviewed-on: https://review.openocd.org/c/openocd/+/7967
Reviewed-by: Bohdan Tymkiv <bohdan200@gmail.com>
Tested-by: jenkins
Reviewed-by: Antonio Borneo <borneo.antonio@gmail.com>
Use a command group 'cmsis-dap' with subcommands instead of individual
commands with 'cmsis_dap_' prefix.
The old commands are still available to ensure backwards compatibility,
but are marked as deprecated.
Change-Id: I75facb7572a86354c2ce6144aa7fadf3b5a6db4e
Signed-off-by: Marc Schink <dev@zapb.de>
Reviewed-on: https://review.openocd.org/c/openocd/+/7963
Reviewed-by: Tomas Vanek <vanekt@fbl.cz>
Tested-by: jenkins
Reviewed-by: Bohdan Tymkiv <bohdan200@gmail.com>
Reviewed-by: Antonio Borneo <borneo.antonio@gmail.com>
This allows programmatically determining the debug reason.
Change-Id: I0c3e85cebb6dc28fc0fc212beca84a484ac654a5
Signed-off-by: Peter Collingbourne <pcc@google.com>
Reviewed-on: https://review.openocd.org/c/openocd/+/7952
Reviewed-by: Jan Matyas <jan.matyas@codasip.com>
Reviewed-by: Tomas Vanek <vanekt@fbl.cz>
Reviewed-by: Antonio Borneo <borneo.antonio@gmail.com>
Tested-by: jenkins
Targets "esp32c2" and "esp32c3" should not be mentioned in the doc
under "target types" because these are not standalone OpenOCD
targets.
They are merely a set of .cfg files which use the generic
"riscv" target.
Signed-off-by: Jan Matyas <jan.matyas@codasip.com>
This patch adds the "all" option to the rwp command.
It removes all watchpoints, much like rbp all removes
all breakpoints.
Change-Id: Id58dd103085e558f17afa4a287888cf085566ca9
Signed-off-by: Marek Vrbka <marek.vrbka@codasip.com>
Reviewed-on: https://review.openocd.org/c/openocd/+/7907
Tested-by: jenkins
Reviewed-by: Antonio Borneo <borneo.antonio@gmail.com>
Previously, if you ran a tcl command in capture like so:
"capture { reg 0x1000 hw }"
Such command did overwrite the tcl result if LOG_LVL_INFO or
lower was logged during it.
This patch changes it by prepending the log to the tcl result instead.
As the tcl results should not be lost during capture.
Change-Id: I37381b45e15c931ba2844d65c9d38f6ed2f6e4fd
Signed-off-by: Marek Vrbka <marek.vrbka@codasip.com>
Reviewed-on: https://review.openocd.org/c/openocd/+/7902
Reviewed-by: Antonio Borneo <borneo.antonio@gmail.com>
Tested-by: jenkins
Reviewed-by: Jan Matyas <jan.matyas@codasip.com>
Add a new riscv specific commands to disable triggers
Change-Id: Ic1842085aa66851c740e0abcbfbe0adbe930920e
Signed-off-by: Kirill Radkin <kirill.radkin@syntacore.com>