yosys/techlibs/intel_alm/common/dsp_sim.v

131 lines
2.2 KiB
Verilog
Raw Normal View History

2021-11-24 15:20:40 -06:00
`default_nettype none
2020-04-25 11:25:59 -05:00
(* abc9_box *)
module MISTRAL_MUL27X27(input [26:0] A, input [26:0] B, output [53:0] Y);
2020-04-25 11:25:59 -05:00
parameter A_SIGNED = 1;
parameter B_SIGNED = 1;
2021-11-24 15:20:40 -06:00
`ifdef cyclonev
specify
(A *> Y) = 3732;
(B *> Y) = 3928;
endspecify
`endif
`ifdef arriav
// NOTE: Arria V appears to have only one set of timings for all DSP modes...
specify
(A *> Y) = 1895;
(B *> Y) = 2053;
endspecify
`endif
`ifdef cyclone10gx
2020-07-21 07:58:38 -05:00
// TODO: Cyclone 10 GX timings; the below are for Cyclone V
2020-04-25 11:25:59 -05:00
specify
2020-07-21 07:58:38 -05:00
(A *> Y) = 3732;
(B *> Y) = 3928;
2020-04-25 11:25:59 -05:00
endspecify
2021-11-24 15:20:40 -06:00
`endif
2020-04-25 11:25:59 -05:00
wire [53:0] A_, B_;
if (A_SIGNED)
assign A_ = $signed(A);
else
assign A_ = $unsigned(A);
if (B_SIGNED)
assign B_ = $signed(B);
else
assign B_ = $unsigned(B);
assign Y = A_ * B_;
2020-04-25 11:25:59 -05:00
endmodule
(* abc9_box *)
module MISTRAL_MUL18X18(input [17:0] A, input [17:0] B, output [35:0] Y);
parameter A_SIGNED = 1;
parameter B_SIGNED = 1;
2021-11-24 15:20:40 -06:00
`ifdef cyclonev
specify
(A *> Y) = 3180;
(B *> Y) = 3982;
endspecify
`endif
`ifdef arriav
// NOTE: Arria V appears to have only one set of timings for all DSP modes...
specify
(A *> Y) = 1895;
(B *> Y) = 2053;
endspecify
`endif
`ifdef cyclone10gx
2020-07-21 07:58:38 -05:00
// TODO: Cyclone 10 GX timings; the below are for Cyclone V
2020-04-25 11:25:59 -05:00
specify
2020-07-21 07:58:38 -05:00
(A *> Y) = 3180;
(B *> Y) = 3982;
2020-04-25 11:25:59 -05:00
endspecify
2021-11-24 15:20:40 -06:00
`endif
2020-04-25 11:25:59 -05:00
wire [35:0] A_, B_;
if (A_SIGNED)
assign A_ = $signed(A);
else
assign A_ = $unsigned(A);
if (B_SIGNED)
assign B_ = $signed(B);
else
assign B_ = $unsigned(B);
assign Y = A_ * B_;
2020-04-25 11:25:59 -05:00
endmodule
(* abc9_box *)
module MISTRAL_MUL9X9(input [8:0] A, input [8:0] B, output [17:0] Y);
parameter A_SIGNED = 1;
parameter B_SIGNED = 1;
2021-11-24 15:20:40 -06:00
`ifdef cyclonev
specify
(A *> Y) = 2818;
(B *> Y) = 3051;
endspecify
`endif
`ifdef arriav
// NOTE: Arria V appears to have only one set of timings for all DSP modes...
specify
(A *> Y) = 1895;
(B *> Y) = 2053;
endspecify
`endif
`ifdef cyclone10gx
2020-07-21 07:58:38 -05:00
// TODO: Cyclone 10 GX timings; the below are for Cyclone V
2020-04-25 11:25:59 -05:00
specify
2020-07-21 07:58:38 -05:00
(A *> Y) = 2818;
(B *> Y) = 3051;
2020-04-25 11:25:59 -05:00
endspecify
2021-11-24 15:20:40 -06:00
`endif
2020-04-25 11:25:59 -05:00
wire [17:0] A_, B_;
if (A_SIGNED)
assign A_ = $signed(A);
else
assign A_ = $unsigned(A);
if (B_SIGNED)
assign B_ = $signed(B);
else
assign B_ = $unsigned(B);
assign Y = A_ * B_;
2020-04-25 11:25:59 -05:00
endmodule