skywater-pdk/docs/rules/periphery/p055-vhvi_dotdash_dotdash.csv

1.3 KiB

1NameDescriptionFlagsValue
2(vhvi.vhv.1)Terminals operating at nominal 12V (maximum 16V) bias must be tagged as Very-High-Voltage (VHV) using vhvi:dg layerNC
3(vhvi.vhv.2)A source or drain of a drain-extended device can be tagged by vhvi:dg. A device with either source or drain (not both) tagged with vhvi:dg serves as a VHV propagation stopperNC
4(vhvi.vhv.3)Any feature connected to VHVSourceDrain becomes a very-high-voltage featureNC
5(vhvi.vhv.4)Any feature connected to VHVPoly becomes a very-high-voltage featureNC
6(vhvi.vhv.5)Diffusion that is not a part of a drain-extended device (i.e., diff not areaid:en) must not be on the same net as VHVSourceDrain. Only diffusion inside :drc_tag:`areaid.ed` and LV diffusion tagged with vhvi:dg are exempted.
7(vhvi.vhv.6)Poly resistor can act as a VHV propagation stopper. For this, it should be tagged with text "vhv_block"NC
8(vhvi.1.-)Min width of vhvi:dg0.020
9(vhvi.2.-)Vhvi:dg cannot overlap areaid:ce
10(vhvi.3.-)VHVGate must overlap hvi:dg
11(vhvi.4.-)Poly connected to the same net as a VHVSourceDrain must be tagged with vhvi:dg layer
12(vhvi.5.-)Vhvi:dg cannot straddle VHVSourceDrain
13(vhvi.6.-)Vhvi:dg overlapping VHVSourceDrain must not overlap poly
14(vhvi.7.-)Vhvi:dg cannot straddle VHVPoly