skywater-pdk/docs/rules/periphery/p051-depmos_dotdash.csv

924 B

1NameDescriptionFlagsValue
2(depmos.1)Min width of de_pFet_gate1.050
3(depmos.2)Min width of de_pFet_source not overlapping poly0.280
4(depmos.3)Min width of de_pFet_source overlapping poly0.920
5(depmos.4)Min width of the de_pFet_drain0.170
6(depmos.5)Min/Max extension of de_pFet_source beyond nwell0.260
7(depmos.6)Min/Max spacing between de_pFet_drain and de_pFet_source1.190
8(depmos.7)Min channel width for de_pFet_gate5.000
9(depmos.8)90 degree angles are not permitted for nwell hole overlapping de_pFET_drain
10(depmos.9a)All bevels on nwell hole are 45 degree, 0.43 um from cornersNC
11(depmos.9b)All bevels on de_pFet_drain are 45 degree, 0.05 um from cornersNC
12(depmos.10)Min enclosure of de_pFet_drain by nwell hole0.860