1.1 KiB
1.1 KiB
1 | Name | Description | Flags | Value |
---|---|---|---|---|
2 | (via3.1) | Min and max L and W of via3 (except for rule via3.1a) | AL | 0.200 |
3 | (via3.1a) | Two sizes of square via3 allowed inside :drc_tag:`areaid.mt`: 0.200um and 0.800um | AL | |
4 | (via3.2) | Spacing of via3 to via3 | AL | 0.200 |
5 | (via3.3) | Only min. square via3s are allowed except die seal ring where via3s are (Via3 CD)*L | 0.2*L | |
6 | (via3.4) | Via3 must be enclosed by Met3 by at least … | AL | 0.060 |
7 | (via3.5) | Via3 must be enclosed by Met3 on one of two adjacent sides by at least … | AL | 0.090 |
8 | (via3.11) | Min and max L and W of via3 | CU | 0.210 |
9 | (via3.12) | Min spacing between via2's | CU | 0.180 |
10 | (via3.13) | Via3 must be enclosed by Met3 by at least … | CU | 0.055 |
11 | (via3.14) | Min spacing between via3 rows | CU | 0.350 |
12 | (via3.irdrop.1) | For 1 <= n <= 2 via3's on the same connector, mcon area pre- and post- Cu conversion must differ by no more than… | CU IR | 0.0 |
13 | (via3.irdrop.2) | For 3 <= n <= 15 via3's on the same connector, mcon area pre- and post- Cu conversion must differ by no more than… | CU IR | 0.6 |
14 | (via3.irdrop.3) | For 16 <= n <= 30 via3's on the same connector, mcon area pre- and post- Cu conversion must differ by no more than… | CU IR | 0.8 |