1NameDescriptionFlagsValueUnit
2(via3.1)Min and max L and W of via3 (except for rule via3.1a)AL0.200µm
3(via3.1a)Two sizes of square via3 allowed inside :drc_tag:`areaid.mt`: 0.200um and 0.800umAL
4(via3.2)Spacing of via3 to via3AL0.200µm
5(via3.3)Only min. square via3s are allowed except die seal ring where via3s are (Via3 CD)*L0.2*L
6(via3.4)Via3 must be enclosed by Met3 by at least …AL0.060µm
7(via3.5)Via3 must be enclosed by Met3 on one of two adjacent sides by at least …AL0.090µm
8(via3.11)Min and max L and W of via3CU0.210µm
9(via3.12)Min spacing between via2'sCU0.180µm
10(via3.13)Via3 must be enclosed by Met3 by at least …CU0.055µm
11(via3.14)Min spacing between via3 rowsCU0.350µm
12(via3.irdrop.1)For 1 <= n <= 2 via3's on the same connector, mcon area pre- and post- Cu conversion must differ by no more than…CU IR0.0µm
13(via3.irdrop.2)For 3 <= n <= 15 via3's on the same connector, mcon area pre- and post- Cu conversion must differ by no more than…CU IR0.6µm
14(via3.irdrop.3)For 16 <= n <= 30 via3's on the same connector, mcon area pre- and post- Cu conversion must differ by no more than…CU IR0.8µm
15(via3.irdrop.4)For n > 30 via3's on the same connector, mcon area pre- and post- Cu conversion must differ by no more than…CU IR0.9µm