skywater-pdk/docs/rules/periphery/p035-ct_dotdash.csv

727 B

1NameDescriptionFlagsValueUnit
2(ct.1)Min and max L and W of mconDNF0.170µm
3(ct.2)Spacing of mcon to mconDNF0.190µm
4(ct.3)Only min. square mcons are allowed except die seal ring where mcons are…0.170*L
5(ct.4)Mcon must be enclosed by LI by at least …P0.000µm
6(ct.irdrop.1)For 1 <= n <= 10 contacts on the same connector, mcon area pre- and post- Cu conversion must differ by no more than…CU IR0.2µm