docs: Adding basic values for capacitance + resistance.
Values taken from the following Google Spreadsheet [SKY130 Stackup Capacitance Data" spreadsheet](https://docs.google.com/spreadsheets/d/1N9To-xTiA7FLfQ1SNzWKe-wMckFEXVE9WPkPPjYkaxE/edit#gid=226894802) Signed-off-by: Tim 'mithro' Ansell <me@mith.ro>
This commit is contained in:
parent
0acfbf84e8
commit
b844d2f081
|
@ -8,9 +8,10 @@ The modeled columns indicate sheets and contacts that are parasitic resistance/c
|
|||
The CAD columns indicate sheets and contacts that are parasitics included in the schematic/layout RCX from Assura.
|
||||
|
||||
.. csv-table:: Parasitic Extraction Table
|
||||
:file: rcx/rcx-all.csv
|
||||
:file: rcx/rcx-all.tsv
|
||||
:header-rows: 2
|
||||
:stub-columns: 1
|
||||
:delim: U+0009
|
||||
|
||||
|
||||
.. note:: The models includes M1/M2 capacitance. As a result of RCX extraction limitation M1/M2 routing over the varactor will have no capacitance extraction.
|
||||
|
@ -33,10 +34,21 @@ Resistance Rules
|
|||
.. todo:: This table should be rendered like the periphery rules.
|
||||
|
||||
.. csv-table:: Table of resistance rules
|
||||
:file: rcx/resistance.csv
|
||||
:header-rows: 2
|
||||
:file: rcx/resistance-rules.csv
|
||||
:stub-columns: 1
|
||||
|
||||
Resistance Values
|
||||
-----------------
|
||||
|
||||
This section includes tables of basic resistance values for SKY130.
|
||||
|
||||
Further data can be found in the `"SKY130 Stackup Capacitance Data" spreadsheet`_.
|
||||
|
||||
.. csv-table:: Table - Resistances
|
||||
:file: rcx/resistance-values.tsv
|
||||
:header-rows: 1
|
||||
:delim: U+0009
|
||||
|
||||
|
||||
Capacitance Rules
|
||||
-----------------
|
||||
|
@ -44,9 +56,57 @@ Capacitance Rules
|
|||
.. todo:: This table should be rendered like the periphery rules.
|
||||
|
||||
.. csv-table:: Table of capacitance rules
|
||||
:file: rcx/capacitance.csv
|
||||
:header-rows: 2
|
||||
:file: rcx/capacitance-rules.csv
|
||||
:stub-columns: 1
|
||||
:delim: U+0009
|
||||
|
||||
|
||||
Capacitance Values
|
||||
------------------
|
||||
|
||||
This section includes tables of basic capacitance values for SKY130.
|
||||
|
||||
Further data can be found in the `"SKY130 Stackup Capacitance Data" spreadsheet`_.
|
||||
|
||||
.. _"SKY130 Stackup Capacitance Data" spreadsheet: https://docs.google.com/spreadsheets/d/1N9To-xTiA7FLfQ1SNzWKe-wMckFEXVE9WPkPPjYkaxE/edit#gid=226894802
|
||||
|
||||
Basic Capacitance - Fringe Downward
|
||||
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
||||
|
||||
Fringe capacitances are a constant value per unit length and are an approximations. Determined by creating a layout with a 5um x 10um rectangle of each layer over or under a much larger rectangle of the other layer. The fringe capacitance computed from the total given minus the parallel plate capacitance.
|
||||
|
||||
"downward direction" means that the larger plate is below the 5um x 10um plate.
|
||||
|
||||
The layer in the first column is always the layer with the 5um x 10um plate.
|
||||
|
||||
.. csv-table:: Table - Capacitance - Fringe Downward
|
||||
:file: rcx/capacitance-fringe-downward.tsv
|
||||
:header-rows: 1
|
||||
:delim: U+0009
|
||||
|
||||
|
||||
Basic Capacitance - Fringe Upward
|
||||
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
||||
|
||||
Fringe capacitances are a constant value per unit length and are an approximations. Determined by creating a layout with a 5um x 10um rectangle of each layer over or under a much larger rectangle of the other layer. The fringe capacitance computed from the total given minus the parallel plate capacitance.
|
||||
|
||||
"upward direction" means that the larger plate is above the 5um x 10um plate.
|
||||
|
||||
The layer in the first column is always the layer with the 5um x 10um plate.
|
||||
|
||||
.. csv-table:: Table - Capacitance - Fringe Upward
|
||||
:file: rcx/capacitance-fringe-upward.tsv
|
||||
:header-rows: 1
|
||||
:delim: U+0009
|
||||
|
||||
|
||||
Basic Capacitance - Parallel
|
||||
~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
||||
|
||||
.. csv-table:: Table - Capacitance - Parallel
|
||||
:file: rcx/capacitance-parallel.tsv
|
||||
:header-rows: 1
|
||||
:delim: U+0009
|
||||
|
||||
|
||||
Discrepencies
|
||||
|
@ -62,3 +122,4 @@ Un-shielded VPP's
|
|||
|
||||
The impact of this on total capacitance and parasitic capacitance is already comprehended in the model corners, however, cross-talk is not modeled. Also, parasitic cap is routed to ground and this may not be ideal for the scenario.
|
||||
The parasitic cap can be estimated using RescapWeb.
|
||||
|
||||
|
|
|
@ -0,0 +1,7 @@
|
|||
Interlayer fringe capacitance (downward direction) (aF/um) Poly Local interconnect Metal1 Metal2 Metal3 Metal4
|
||||
Local interconnect 51.846
|
||||
Metal1 46.724 59.496
|
||||
Metal2 41.222 46.277 67.045
|
||||
Metal3 43.531 46.708 54.814 69.846
|
||||
Metal4 38.105 39.709 42.563 46.382 70.522
|
||||
Metal5 39.908 41.147 43.188 45.592 54.152 82.819
|
|
|
@ -0,0 +1,7 @@
|
|||
Interlayer fringe capacitance (upward direction) (aF/um) Local interconnect Metal1 Metal2 Metal3 Metal4 Metal5
|
||||
Poly 25.138 16.691 11.166 9.18 6.3505 6.4903
|
||||
Local interconnect 34.7 21.739 15.078 10.141 7.6366
|
||||
Metal1 48.193 26.676 16.421 12.017
|
||||
Metal2 44.432 22.332 15.693
|
||||
Metal3 42.643 27.836
|
||||
Metal4 46.976
|
|
|
@ -0,0 +1,7 @@
|
|||
Interlayer parallel plate capacitance (aF/um^2) Local interconnect Metal1 Metal2 Metal3 Metal4 Metal5
|
||||
Poly 94.1644 44.8056 24.4968 16.0552 10.0131 7.2085
|
||||
Local interconnect 114.1970 37.5647 20.7915 11.6705 8.0265
|
||||
Metal1 133.8610 34.5350 15.0275 9.4789
|
||||
Metal2 86.1861 20.3321 11.3410
|
||||
Metal3 84.0346 19.6269
|
||||
Metal4 68.3252
|
|
|
@ -1,4 +1,4 @@
|
|||
,General(CAP.-)
|
||||
,General (CAP.-)
|
||||
.X.1,No capacitance is extracted due to contacts. (This is a generic layout extraction tool limitation.)
|
||||
|
||||
,MOS Devices (MOS.-)
|
Can't render this file because it has a wrong number of fields in line 9.
|
|
@ -1,4 +1,4 @@
|
|||
,General (RES.-)
|
||||
,General (RES.-)
|
||||
.X,Parasitic resistance is not extrated under a sheet layer with it's corresponding res.id layer.
|
||||
|
||||
,Sheet Resistance (SR.-)
|
Can't render this file because it has a wrong number of fields in line 5.
|
|
@ -0,0 +1,23 @@
|
|||
Layer Resistivity (mohms/sq)
|
||||
Poly 48200
|
||||
Local interconnect 12800
|
||||
Metal1 125
|
||||
Metal2 125
|
||||
Metal3 47
|
||||
Metal4 47
|
||||
Metal5 29
|
||||
Deep nwell 2200000
|
||||
Pwell (in deep nwell) 3050000
|
||||
Nwell 1700000
|
||||
N-diffusion 120000
|
||||
P-diffusion 197000
|
||||
HV N-diffusion 114000
|
||||
HV P-diffusion 191000
|
||||
XHR poly resistor 319800
|
||||
UHR poly resistor 2000000
|
||||
LICON contact 15000
|
||||
MCON contact 152000
|
||||
VIA 4500
|
||||
VIA2 3410
|
||||
VIA3 3410
|
||||
VIA4 380
|
|
Loading…