Parasitic Layout Extraction
|
||
|
===========================
|
||
|
|
||
|
This table list layers and contacts included in SPICE models, and parasitic layers include in the AssuraLayout Extraction.
|
||
|
|
||
|
The modeled columns indicate sheets and contacts that are parasitic resistance/capacitance included in the model extraction measurements.
|
||
|
|
||
|
The CAD columns indicate sheets and contacts that are parasitics included in the schematic/layout RCX from Assura.
|
||
|
|
||
|
.. csv-table:: Parasitic Extraction Table
|
||
|
:file: rcx/rcx-all.csv
|
||
|
:header-rows: 2
|
||
|
|
||
|
|
||
|
.. note:: The models includes M1/M2 capacitance. As a result of RCX extraction limitation M1/M2 routing over the varactor will have no capacitance extraction.
|
||
|
|
||
|
Routing and placement of devices over or under Precision resistors (xhrpoly_X_X) should be avoided.
|
||
|
|
||
|
The parasitic capacitance between 3-terminal MIMC and any routing/devices is not included in layout RCX, except M3 by 1 snap grid width.
|
||
|
|
||
|
No artificial fringing capacitance is extracted for MIMC M2/M3 due to CAD algorithm after CAPM sizing.
|
||
|
|
||
|
The parasitic capacitance between Precision resistors (xhrpoly_X_X) and any routing/devices is not included in layout RCX.
|
||
|
|
||
|
S8Q-5R is not supported for RF ESD diode RCX blocking.
|
||
|
|
||
|
The ``areaid:substratecut`` will be extracted as a 0.123 ohm two terms resistor.
|
||
|
|
||
|
Resistance Rules
|
||
|
----------------
|
||
|
|
||
|
.. todo:: This table should be rendered like the periphery rules.
|
||
|
|
||
|
.. csv-table:: Table of resistance rules
|
||
|
:file: rcx/resistance.csv
|
||
|
:header-rows: 2
|
||
|
|
||
|
|
||
|
Capacitance Rules
|
||
|
-----------------
|
||
|
|
||
|
.. todo:: This table should be rendered like the periphery rules.
|
||
|
|
||
|
.. csv-table:: Table of capacitance rules
|
||
|
:file: rcx/capacitance.csv
|
||
|
:header-rows: 2
|
||
|
|
||
|
|
||
|
Discrepencies
|
||
|
-------------
|
||
|
|
||
|
Non-precision poly resistors
|
||
|
These resistors do not extract capacitance to substrate.
|
||
|
|
||
|
This needs to be accounted for manually by using ICPS_0150_0210 (cap per perimeter), and ICPS_2000_4000 (cap per area).
|
||
|
|
||
|
Un-shielded VPP's
|
||
|
Any routing above an un-shielded VPP will not be extracted.
|
||
|
|
||
|
The impact of this on total capacitance and parasitic capacitance is already comprehended in the model corners, however, cross-talk is not modeled. Also, parasitic cap is routed to ground and this may not be ideal for the scenario.
|
||
|
The parasitic cap can be estimated using RescapWeb.
|