.mos.5,All 20V NMOS ISO DEFETs will have the parasitic diode included in the models.,This model also includes the 5th terminal Drain-Psub diode (DeepNwell - Psub).
.mos.7,The only 20V DEFET instance parameter that the model uses from CAD extraction is m-factor.,The model will over-write all other instance parameters from CAD extraction.
.res.1,short devices must not have capacitance calculated across the device.,
.res.2,fuse devices must have capacitance extracted.,
.res.3,poly resistors that are not the precision poly resistors (xhrpoly_X_X) must have capacitance extracted.,
.res.4,metops that are merged must have capacitance extracted.,
.res.5,parasitic resistors for diff/nwell must have the junction diode extracted.,
.res.6,Poly precision resistors must not have the poly-psub parasitic capacitance extracted (RCX should also exclude head/tail poly-psub capacitance).,
.res.7,"For Poly precision resistors xhrpoly_X_1, the device recognition layer is defined by growing the poly.rs AND rpm.dg layers 0.50 um(head/tail distance from ID layer) in all directions. Poly-Field/Diff/Well, and Poly-Poly, Poly-Li will not have capacitance extracted inside this device recognition layer.",
.res.8,"For Poly precision resistors xhrpoly_X_2, the device recognition layer is defined by growing the poly.rs AND rpm.dg layers 1.18 um(head/tail distance from ID layer) in all directions. Poly-Field/Diff/Well, and Poly-Poly, Poly-Li will not have capacitance extracted inside this device recognition layer.",
,,
,Capacitors (PASSIVES.-),
.cnwvc.1,"capacitance will not be extracted for field, diff, Poly, Li, M1, M2 up to 0.465u away from device\n recognition layer (as defined in LVS table of TDR)",
.cmimc.1,"capacitance will not be extracted between M2 to field, diff, Poly, Li, M1 up to 0.14u away from device\n recognition layer (intersection of M2 overlapping CAPM that's connected to VIA2, 3-terminal MiM only)",
.crfesd.1,"capacitance will not be extracted for field, diff, Poly, Li, M1, M2 up to 0.4u away from device recognition layers (diode terminals)",
.xcmvpp.1," For Cap extraction of xcmvpp11p5x11p7_polym50p4shield, the metal5 exposed for metal5-metal5 capacitance extraction is an extra 0.4um from the extraction of xcmvpp11p5x11p7_polym5shield. For any layer below metal5, the capcitance extraction of xcmvpp11p5x11p7_polym50p4shield is the same as xcmvpp11p5x11p7_polym5shield (Note: for the unit cel xcmvpp11p5x11p7_polym50p4shield metal5 is pulled in 0.4um from the cell edge)",