Firstly, create the TPIU nrf52.tpiu if using the nrf52 target. This is
standard, using AP 0 and TPIU base address 0xE0040000.
Secondly, add a pre_enable handler for this TPIU which configures the
TRACEMUX field of the TRACECONFIG register. This register is reset
every time the MCU resets, so the pre_enable handler creates a
reset-end handler to ensure the register remains set.
Change-Id: I408b20fc03dc2060c21bad0c21ed713eee55a113
Signed-off-by: Frank Plowman <post@frankplowman.com>
Reviewed-on: https://review.openocd.org/c/openocd/+/7901
Reviewed-by: Antonio Borneo <borneo.antonio@gmail.com>
Tested-by: jenkins