.. list-table::
:header-rows: 1
:stub-columns: 1
* - Condition
- V\ :sub:`G`
- V\ :sub:`D`
- V\ :sub:`B`
- V\ :sub:`S`
- V\ :sub:`WL`
- Pulse
* - Read
- 0
- +1.1
- 0
- 0
- +1.8
- n/a
* - Program
- +6.7
- -3.8
- -3.8
- -38
- Float
- 2 ms
* - Erase
- -3.8
- +6.7
- +6.7
- +6.7
- Float
- 6 ms
* - VT meas
- I\ :sub:`D` = 2.05µA
- +1.1
- 0
- 0
- +1.8
- n/a