.. _direct_interconnect:
Direct Interconnect
-------------------
This section introduces extensions on the architecture description file about direct connections between programmable blocks.
Syntax
~~~~~~
The original direct connections in the directlist section are documented here_. Its description is given below:
.. _here: http://docs.verilogtorouting.org/en/latest/arch/reference/?highlight=directlist#direct-inter-block-connections
.. code-block:: xml
.. note:: These options are required
In the OpenFPGA architecture file, you may define additional attributes for each VPR's direct connection:
.. code-block:: xml
.. note:: these options are optional. However, if ``interconnection_type`` is set to ``inter_column`` or ``inter_row``, then ``x_dir`` and ``y_dir`` are required.
.. option:: interconnection_type=""
Available types are ``inner_column_or_row`` | ``part_of_cb`` | ``inter_column`` | ``inter_row``
- ``inner_column_or_row`` indicates the direct connections are between tiles in the same column or row. This is the default value.
- ``part_of_cb`` indicates the direct connections will drive routing multiplexers in connection blocks. Therefore, it is no longer a strict point-to-point direct connection.
- ``inter_column`` indicates the direct connections are between tiles in two columns
- ``inter_row`` indicates the direct connections are between tiles in two rows
.. note:: The following syntax is only applicable to ``inter_column`` and ``inter_row``
.. option:: x_dir=""
Available directionalities are ``positive`` | ``negative``, specifies if the next cell to connect has a bigger or lower ``x`` value.
Considering a coordinate system where (0,0) is the origin at the bottom left and ``x`` and ``y`` are positives:
- x_dir="positive":
- interconnection_type="inter_column": a column will be connected to a column on the ``right``, if it exists.
- interconnection_type="inter_row": the most on the ``right`` cell from a row connection will connect the most on the ``left`` cell of next row, if it exists.
- x_dir="negative":
- interconnection_type="inter_column": a column will be connected to a column on the ``left``, if it exists.
- interconnection_type="inter_row": the most on the ``left`` cell from a row connection will connect the most on the ``right`` cell of next row, if it exists.
.. option:: y_dir=""
Available directionalities are ``positive`` | ``negative``, specifies if the next cell to connect has a bigger or lower x value.
Considering a coordinate system where (0,0) is the origin at the bottom left and `x` and `y` are positives:
- y_dir="positive":
- interconnection_type="inter_column": the ``bottom`` cell of a column will be connected to the next column ``top`` cell, if it exists.
- interconnection_type="inter_row": a row will be connected on an ``above`` row, if it exists.
- y_dir="negative":
- interconnection_type="inter_column": the ``top`` cell of a column will be connected to the next column ``bottom`` cell, if it exists.
- interconnection_type="inter_row": a row will be connected on a row ``below``, if it exists.
Enhanced Connection Block
~~~~~~~~~~~~~~~~~~~~~~~~~
The direct connection can also drive routing multiplexers of connection blocks. When such connection occures in a connection block, it is called enhanced connection block.
:numref:`fig_ecb` illustrates the difference between a regular connection block and an enhanced connection block.
.. _fig_ecb:
.. figure:: ./figures/ecb.png
Enhanced connection block vs. Regular connection block
In such scenario, the type ``part_of_cb`` is required.
.. warning:: Restrictions may be applied when building the direct connections as part of a connection block.
Direct connections can be inside a tile or across two tiles. Currently, across more than two tiles are not supported!
:numref:`fig_ecb_allowed_direct_connection` illustrates the region (in red) where any input pin is allowed to be driven by any output pin.
.. _fig_ecb_allowed_direct_connection:
.. figure:: ./figures/ecb_allowed_direct_connection.png
Allowed connections inside a tile for enhanced connection block (see the highlighted region)
:numref:`fig_ecb_allowed_direct_connection_inner_tile_example` shows a few feedback connections which can be built inside connection blocks. Note that feedback connections are fully allowed between any pins on the same side of a programmable block.
.. _fig_ecb_allowed_direct_connection_inner_tile_example:
.. figure:: ./figures/ecb_allowed_direct_connection_inner_tile_example.png
Example of feedback connections inside a tile for enhanced connection block
For instance, VPR architecture defines feedback connections like:
.. code-block:: xml
:numref:`fig_ecb_allowed_direct_connection_inter_tile_example` shows a few inter-tile connections which can be built inside connection blocks. Note that inter-tile connections are subjected to the restrictions depicted in :numref:`fig_ecb_allowed_direct_connection`
.. _fig_ecb_allowed_direct_connection_inter_tile_example:
.. figure:: ./figures/ecb_allowed_direct_connection_inter_tile_example.png
Example of connections across two tiles for enhanced connection block
:numref:`fig_ecb_forbid_direct_connection_example` illustrates some inner-tile and inter-tile connections which are not allowed. Note that feedback connections across different sides are restricted!
.. _fig_ecb_forbid_direct_connection_example:
.. figure:: ./figures/ecb_forbid_direct_connection_example.png
Restrictions on building direct connections as part of a connection block
Inter-tile Connections
~~~~~~~~~~~~~~~~~~~~~~
For this example, we will study a scan-chain implementation. The description could be:
In VPR architecture:
.. code-block:: xml
In OpenFPGA architecture:
.. code-block:: xml
:numref:`fig_p2p_exple` is the graphical representation of the above scan-chain description on a 4x4 FPGA.
.. _fig_p2p_exple:
.. figure:: ./figures/point2point_example.png
An example of scan-chain implementation
In this figure, the red arrows represent the initial direct connection. The green arrows represent the point to point connection to connect all the columns of CLB.
A point to point connection can be applied in different ways than showed in the example section. To help the designer implement his point to point connection, a truth table with our new parameters id provided below.
:numref:`fig_p2p_trtable` provides all possible variable combination and the connection it will generate.
.. _fig_p2p_trtable:
.. figure:: ./figures/point2point_truthtable.png
Point to point truth table