Every TCL command can be renamed (or deleted) and then replaced by a TCL proc that has the same name of the original TCL command. This can be used either to completely replace an existing command or to wrap the original command to extend its functionality. This applies also to the OpenOCD command "shutdown" and can be useful, for example, to set back some default value to the target before quitting OpenOCD. E.g. (TCL code): rename shutdown original_shutdown proc shutdown {} { puts "This is my implementation of shutdown" # my own stuff before exit OpenOCD original_shutdown } Unfortunately, sending a signal (or pressing CTRL-C) to terminate OpenOCD doesn't trigger calling the original "shutdown" command nor its (eventual) replacement. Detect if the main loop is terminated by an external signal and in such case execute explicitly the command "shutdown". Replace with enum the magic numbers assumed by "shutdown_openocd". Please notice that it's possible to write a custom "shutdown" TCL proc that does not call the original "shutdown" command. This is useful, for example, to prevent the user to quit OpenOCD by typing "shutdown" in the telnet session. Such case will not prevent OpenOCD to terminate when receiving a signal; OpenOCD will quit after executing the custom "shutdown" command. Change-Id: I86b8f9eab8dbd7a28dad58b8cafd97caa7a82f43 Signed-off-by: Antonio Borneo <borneo.antonio@gmail.com> Reviewed-on: http://openocd.zylin.com/4551 Tested-by: jenkins Reviewed-by: Tomas Vanek <vanekt@fbl.cz> |
||
---|---|---|
.. | ||