Fix reset for multicore.
This commit is contained in:
parent
848fe0ffcf
commit
fe36097ff8
|
@ -1185,21 +1185,42 @@ static int examine(struct target *target)
|
|||
|
||||
static int assert_reset(struct target *target)
|
||||
{
|
||||
/*FIXME -- this only works for single-hart.*/
|
||||
RISCV_INFO(r);
|
||||
assert(r->current_hartid == 0);
|
||||
|
||||
select_dmi(target);
|
||||
|
||||
uint32_t control = 0;
|
||||
control = set_field(control, DMI_DMCONTROL_HALTREQ, target->reset_halt ? 1 : 0);
|
||||
control = set_field(control, DMI_DMCONTROL_HARTRESET, 1);
|
||||
control = set_field(control, DMI_DMCONTROL_NDMRESET, 1);
|
||||
control = set_field(control, DMI_DMCONTROL_HARTSEL, r->current_hartid);
|
||||
control = set_field(control, DMI_DMCONTROL_DMACTIVE, 1);
|
||||
uint32_t control_base = set_field(0, DMI_DMCONTROL_DMACTIVE, 1);
|
||||
|
||||
LOG_DEBUG("write 0x%x to dmcontrol", control);
|
||||
dmi_write(target, DMI_DMCONTROL, control);
|
||||
if (target->rtos) {
|
||||
// There's only one target, and OpenOCD thinks each hart is a thread.
|
||||
// We must reset them all.
|
||||
|
||||
// TODO: Try to use hasel in dmcontrol
|
||||
|
||||
// Set haltreq/resumereq for each hart.
|
||||
uint32_t control = control_base;
|
||||
for (int i = 0; i < riscv_count_harts(target); ++i) {
|
||||
if (!riscv_hart_enabled(target, i))
|
||||
continue;
|
||||
|
||||
control = set_field(control_base, DMI_DMCONTROL_HARTSEL, i);
|
||||
control = set_field(control, DMI_DMCONTROL_HALTREQ,
|
||||
target->reset_halt ? 1 : 0);
|
||||
dmi_write(target, DMI_DMCONTROL, control);
|
||||
}
|
||||
// Assert ndmreset
|
||||
control = set_field(control, DMI_DMCONTROL_NDMRESET, 1);
|
||||
dmi_write(target, DMI_DMCONTROL, control);
|
||||
|
||||
} else {
|
||||
// Reset just this hart.
|
||||
uint32_t control = set_field(control_base, DMI_DMCONTROL_HARTSEL,
|
||||
r->current_hartid);
|
||||
control = set_field(control, DMI_DMCONTROL_HALTREQ,
|
||||
target->reset_halt ? 1 : 0);
|
||||
control = set_field(control, DMI_DMCONTROL_HARTRESET, 1);
|
||||
dmi_write(target, DMI_DMCONTROL, control);
|
||||
}
|
||||
|
||||
target->state = TARGET_RESET;
|
||||
|
||||
|
@ -1212,10 +1233,7 @@ static int deassert_reset(struct target *target)
|
|||
RISCV013_INFO(info);
|
||||
select_dmi(target);
|
||||
|
||||
/*FIXME -- this only works for Single Hart*/
|
||||
assert(r->current_hartid == 0);
|
||||
|
||||
/*FIXME -- is there bookkeeping we need to do here*/
|
||||
LOG_DEBUG("%d", r->current_hartid);
|
||||
|
||||
// Clear the reset, but make sure haltreq is still set
|
||||
uint32_t control = 0;
|
||||
|
|
Loading…