target: clear running_alg flag after reset
After the target was reset we can be sure it's not running any algorithm. This fixes the following failure scenario: On my STM32F103 board after I start the firmware and then stop and try to "load" in gdb (before doing mon reset halt), I get Error: timeout waiting for algorithm, a target reset is recommended However, target reset doesn't help as the flag is still there ("Error: Target is already running an algorithm"), so I have no choice but to restart the OpenOCD process. I'm not sure yet what exactly prevents load from working after my firmware is initialised, most probably some interrupt is firing and my handler produces a fault due to garbled RAM. Change-Id: Idd977f2780a64d84800e3abd412cffc1ab6801b0 Signed-off-by: Paul Fertser <fercerpav@gmail.com> Reviewed-on: http://openocd.zylin.com/1512 Tested-by: jenkins Reviewed-by: Spencer Oliver <spen@spen-soft.co.uk>
This commit is contained in:
parent
fccc55225a
commit
01dde68a4b
|
@ -583,8 +583,10 @@ static int target_process_reset(struct command_context *cmd_ctx, enum target_res
|
|||
retval = target_call_timer_callbacks_now();
|
||||
|
||||
struct target *target;
|
||||
for (target = all_targets; target; target = target->next)
|
||||
for (target = all_targets; target; target = target->next) {
|
||||
target->type->check_reset(target);
|
||||
target->running_alg = false;
|
||||
}
|
||||
|
||||
return retval;
|
||||
}
|
||||
|
|
Loading…