86 lines
3.0 KiB
INI
86 lines
3.0 KiB
INI
|
[BOM_OPTIONS]
|
||
|
; General BoM options here
|
||
|
; If 'ignore_dnf' option is set to 1, rows that are not to be fitted on the PCB will not be written to the BoM file
|
||
|
ignore_dnf = 1
|
||
|
; If 'use_alt' option is set to 1, grouped references will be printed in the alternate compressed style eg: R1-R7,R18
|
||
|
use_alt = 0
|
||
|
; If 'alt_wrap' option is set to and integer N, the references field will wrap after N entries are printed
|
||
|
alt_wrap = 0
|
||
|
; If 'number_rows' option is set to 1, each row in the BoM will be prepended with an incrementing row number
|
||
|
number_rows = 1
|
||
|
; If 'group_connectors' option is set to 1, connectors with the same footprints will be grouped together, independent of the name of the connector
|
||
|
group_connectors = 1
|
||
|
; If 'test_regex' option is set to 1, each component group will be tested against a number of regular-expressions (specified, per column, below). If any matches are found, the row is ignored in the output file
|
||
|
test_regex = 1
|
||
|
; If 'merge_blank_fields' option is set to 1, component groups with blank fields will be merged into the most compatible group, where possible
|
||
|
merge_blank_fields = 1
|
||
|
; If '{opt}' option is set to 1, the schematic version number will be appended to the filename.
|
||
|
include_version_number = 1
|
||
|
; Field name used to determine if a particular part is to be fitted
|
||
|
fit_field = Config
|
||
|
; Make a backup of the bom before generating the new one, using the folloing template
|
||
|
make_backup = %O.tmp
|
||
|
|
||
|
[IGNORE_COLUMNS]
|
||
|
; Any column heading that appears here will be excluded from the Generated BoM
|
||
|
; Titles are case-insensitive
|
||
|
Part Lib
|
||
|
Footprint Lib
|
||
|
|
||
|
[COLUMN_ORDER]
|
||
|
; Columns will apear in the order they are listed here
|
||
|
; Titles are case-insensitive
|
||
|
Description
|
||
|
Part
|
||
|
Part Lib
|
||
|
References
|
||
|
Value
|
||
|
Footprint
|
||
|
Footprint Lib
|
||
|
Quantity Per PCB
|
||
|
Build Quantity
|
||
|
Datasheet
|
||
|
|
||
|
[GROUP_FIELDS]
|
||
|
; List of fields used for sorting individual components into groups
|
||
|
; Components which match (comparing *all* fields) will be grouped together
|
||
|
; Field names are case-insensitive
|
||
|
Part
|
||
|
Part Lib
|
||
|
Value
|
||
|
Footprint
|
||
|
Footprint Lib
|
||
|
|
||
|
[COMPONENT_ALIASES]
|
||
|
; A series of values which are considered to be equivalent for the part name
|
||
|
; Each line represents a tab-separated list of equivalent component name values
|
||
|
; e.g. 'c c_small cap' will ensure the equivalent capacitor symbols can be grouped together
|
||
|
; Aliases are case-insensitive
|
||
|
c c_small cap capacitor
|
||
|
r r_small res resistor
|
||
|
sw switch
|
||
|
l l_small inductor
|
||
|
zener zenersmall
|
||
|
d diode d_small
|
||
|
|
||
|
[REGEX_INCLUDE]
|
||
|
; A series of regular expressions used to include parts in the BoM
|
||
|
; If there are any regex defined here, only components that match against ANY of them will be included in the BOM
|
||
|
; Column names are case-insensitive
|
||
|
; Format is: "ColumName Regex" (tab-separated)
|
||
|
|
||
|
[REGEX_EXCLUDE]
|
||
|
; A series of regular expressions used to exclude parts from the BoM
|
||
|
; If a component matches ANY of these, it will be excluded from the BoM
|
||
|
; Column names are case-insensitive
|
||
|
; Format is: "ColumName Regex" (tab-separated)
|
||
|
References ^TP[0-9]*
|
||
|
References ^FID
|
||
|
Part mount.*hole
|
||
|
Part solder.*bridge
|
||
|
Part test.*point
|
||
|
Footprint test.*point
|
||
|
Footprint mount.*hole
|
||
|
Footprint fiducial
|
||
|
|